Skip to Main Content
Integration


This is an IBM Automation portal for Integration products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.


ADD A NEW IDEA

My ideas: DataPower Gateway

Showing 369 of 3280

Update key algorithms

The customer has updated their workstation to RHEL9, since RHEL9 does not support for key algorithms rsa, and failed to ssh to the DataPower Gateway CLI
over 1 year ago in DataPower Gateway 1 Functionality already exists

common error code for backside timeouts

In case of a backside connection timeout within WSP or MPGW service, DataPower just sets the standard "failed to establish backside connection" error code 0x01130006 instead of a dedicated error code indicating the timeout. Only the XMLFW service ...
over 6 years ago in DataPower Gateway 0 Future consideration

improve LoadBalancerStatus2 information

The LoadBalancerStatus2 page currently shows only the opstate and adminstate of the load balancer group members but not of the load balancer group object itself.This can be confusing in cases where the members are still enabled but the actual LBG ...
over 6 years ago in DataPower Gateway 0 Future consideration

Import Files improvement

In the Import Files functionality, it is not easy to determine if it is processing or not, so it is suggested that once it starts, block the start button, so that it cannot be clicked again until it finishes. I tested this in the operator versions...
over 1 year ago in DataPower Gateway 2 Not under consideration

Datapower LDAP group Authorization

DataPower does not support group member range retrieval.
over 6 years ago in DataPower Gateway 0 Future consideration

Allow JSON schema validation via URL to use HTTPS

If you use a https url for JSON schema validation it will fail to communicate because a TLS profile wasn't selected. There is no way to select a TLS profile. This is baked into Datapower 10.5.0.10 as well. Example of error: Cannot establish TLS cr...
over 1 year ago in DataPower Gateway 0 Future consideration

SOAP Security Signature not correct - Namespace prefix for id-attribute is missing

In W3C specification of SOAP Security Extension (https://www.w3.org/TR/2001/NOTE-SOAP-dsig-20010206/) in chapter "2.3 SOAP-SEC:id Attribute" is the reference attribute "id" defined with an namespace prefix of xmlns:SOAP-SEC="http://schemas.xmlsoap...
almost 7 years ago in DataPower Gateway 0 Not under consideration

REST API JSON response unification

If you query for Object which has multiple childs, JSON response will contain a list, eg. [{}, {}, {}, ...]But if same object has only one child, JSON response does not contain list but directly child, eg. {} Feature should be, that if only one ch...
about 7 years ago in DataPower Gateway 1 Not under consideration

Code/Unit Test Coverage for DataPower services

We would like to determine the code/unit test coverage for a DataPower service(config+XSLT+GWScript) when we execute unit/integration test cases for that particular service. This will help us understand if our test cases are adequate to cover majo...
over 5 years ago in DataPower Gateway 0 Future consideration

IMSConnect : TransactionId in ascii implies all remaining data flow conversion

According to "ftp://public.dhe.ibm.com/software/IMS/documentation/ims15pdfs/IMS_15_Communications_and_Connections.pdf" page 351, when the TransactionId ( setup within the xslt ) is in ascii and the remaining code is in unicode ( or utf8 or ascii )...
over 5 years ago in DataPower Gateway 3 Future consideration