Skip to Main Content
Integration


This is an IBM Automation portal for Integration products. To view all of your ideas submitted to IBM, create and manage groups of Ideas, or create an idea explicitly set to be either visible by all (public) or visible only to you and IBM (private), use the IBM Unified Ideas Portal (https://ideas.ibm.com).


Shape the future of IBM!

We invite you to shape the future of IBM, including product roadmaps, by submitting ideas that matter to you the most. Here's how it works:

Search existing ideas

Start by searching and reviewing ideas and requests to enhance a product or service. Take a look at ideas others have posted, and add a comment, vote, or subscribe to updates on them if they matter to you. If you can't find what you are looking for,

Post your ideas
  1. Post an idea.

  2. Get feedback from the IBM team and other customers to refine your idea.

  3. Follow the idea through the IBM Ideas process.


Specific links you will want to bookmark for future use

Welcome to the IBM Ideas Portal (https://www.ibm.com/ideas) - Use this site to find out additional information and details about the IBM Ideas process and statuses.

IBM Unified Ideas Portal (https://ideas.ibm.com) - Use this site to view all of your ideas, create new ideas for any IBM product, or search for ideas across all of IBM.

ideasibm@us.ibm.com - Use this email to suggest enhancements to the Ideas process or request help from IBM for submitting your Ideas.


ADD A NEW IDEA

Ideas

Showing 281

Monitoring events logging to ELK

Currently only system logs (BIP, ...) are sent over ELK configuration to Logstash agent. We would like to write also monitoring events directly to Logstash agent.Currently, ACE supports logging monitoring events only via MQ/MQTT to topic.
almost 5 years ago in App Connect 2 Delivered

Move Client Channel Buffers above the bar

This RFE is a request to have the option to move client channel (transmission) buffers above the bar We are running MQv8 on z/OS. Datapower has numerous client connections to this MQ transmitting very large messages. Our CHIN storage below the bar...
over 8 years ago in MQ, MQ Advanced & MQ Appliance 4 Delivered

Support DB/2 on z/OS with Designer in ACE CC

We use ACE in our legacy Datacenter to connect to DB/2. At the moment, we cannot use Designer for this because z/OS is not supported in the DB/2 Connector. Also it is not possible to add additional JDBC drivers to work around the connecitivity iss...
about 1 year ago in App Connect 4 Delivered

Request to include an API success and total counts in the SMF 115.

We have a requirement to enhance the SMF 115. The SMF 115, the MQ Statistical data, reports on the number of API requests that have been issued, but It does not report on how many complete with good completion and reason codes. We would request to...
almost 10 years ago in MQ, MQ Advanced & MQ Appliance 5 Delivered

Support TLS v 1.3 in IIB v 10.

In order to use TLS 1.3, we think that it should be enable using TLS for both inbound and outbound traffic, in IBM INTEGRATION BUS V 10.0.
almost 5 years ago in App Connect 2 Delivered

Support configuration use of individual MQ AppName at the Message Flow MQ Connection Level in IIB and ACE.

This is a request for IIB/ACE to provide configurable support in different application Message Flow based connections/usage to specify unique/different MQ AppName identifiers across different types of connections within a Broker and within Applica...
over 5 years ago in App Connect 2 Delivered

MQIPT (MS81) TLS Server Name Indication (SNI) Pass-through Support

Enhance MQ IPT to support the pass through of Server Name Indication (SNI) during TLS handshake
almost 7 years ago in MQ, MQ Advanced & MQ Appliance 4 Delivered

Advanced filters for IBM MQ Explorer

IBM MQ Explorer (MS0T) has been used as an administrative tool for MQAs only, but nowadays app supports experts and final users (developers, service owners, NOC operators, etc) need this tool for restricted administrative tasks (e.g. enabling or d...
over 6 years ago in MQ, MQ Advanced & MQ Appliance 1 Delivered

KafkaConsumer Node allows multiple consumers in a CGID under "Additional Instance" setting

We would like to scale our ACE12 flow performance based on KafkaConsumer input node and its Additional Instance setting. Let's say our Kafka topic partition is 100 partitions. Our other Java program can easily scale up from single consumer/thread ...
over 1 year ago in App Connect 1 Delivered

Create new queue managers with BSDS version 2

With version 8 of MQ,came a new enhancement to increase the Log RBA from 6 bytes to 8 bytes.To implement this feature we have to run a utility CSQJUCNV which coverts BSDS version 1 to version 2 and as part of this process we are able to exploit 8 ...
over 6 years ago in MQ, MQ Advanced & MQ Appliance 1 Delivered